{"id":61696,"date":"2026-11-06T17:37:32","date_gmt":"2026-11-06T15:37:32","guid":{"rendered":"https:\/\/www.craftoil.net\/product\/maslostantsiia-hidravlichna-dvopotokova-3-kvt-380-v-bak-30-l\/"},"modified":"2026-11-06T17:48:43","modified_gmt":"2026-11-06T15:48:43","slug":"maslostantsiia-hidravlichna-dvopotokova-3-kvt-380-v-bak-30-l","status":"publish","type":"product","link":"https:\/\/www.craftoil.net\/en\/product\/maslostantsiia-hidravlichna-dvopotokova-3-kvt-380-v-bak-30-l\/","title":{"rendered":"3 kW Three-Phase Double-Acting Hydraulic Power Unit, 380 V, 30 L Tank"},"content":{"rendered":"<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">3 kW electric motor \u00b7 380 V three-phase supply \u00b7 700 bar maximum operating pressure \u00b7 30 L oil tank \u00b7 Double-acting hydraulic circuit<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Industrial hydraulic power for demanding applications and repeated work cycles. The CraftOil 3 kW three-phase double-acting hydraulic power unit is designed for industrial workshops, manufacturing facilities and service centres that require reliable high-pressure hydraulic power for repeated operations.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The unit combines a two-stage hydraulic pump, a 30-litre oil reservoir, remote control and a double-acting hydraulic circuit. It delivers a specified flow rate of 14 L\/min at the first stage and 2.8 L\/min at the high-pressure stage, with a maximum operating pressure of 70 MPa (700 bar).<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">This version is designed for a 380 V three-phase electrical supply. Compared with the corresponding 220 V single-phase version, the hydraulic specifications are the same, while the electrical connection and motor configuration differ.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">If your facility already has a suitable three-phase supply, this model is worth considering for frequent hydraulic operations where higher flow and a suitable industrial electrical installation are important.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">CraftOil provides equipment selection assistance, technical support and spare-parts service in Ukraine.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Key Benefits<\/b><\/span><\/span><\/p>\n<ul>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>3 kW electric motor:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> designed for demanding applications and frequent work cycles.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>380 V three-phase supply:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> suitable for facilities equipped with a compatible three-phase electrical connection.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Up to 700 bar operating pressure:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> for compatible hydraulic equipment rated for the required pressure.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Two-stage pump:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> combines higher flow at low pressure with lower flow at high pressure.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>14 L\/min first-stage flow:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> supports faster initial cylinder movement when the pump is operating in its first stage.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>2.8 L\/min high-pressure flow:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> helps reduce hydraulic working-stroke time compared with lower-flow models.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Double-acting hydraulic circuit:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> enables powered extension and retraction of compatible cylinders.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>30 L oil reservoir:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> provides an oil supply for appropriately sized hydraulic systems.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Remote control:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> allows the operator to control the unit from the working position.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Glycerine-filled pressure gauge:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> helps dampen needle vibration for easier pressure monitoring.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>CraftOil technical support:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> assistance with model selection, connection questions and spare parts in Ukraine.<\/span><\/span><\/p>\n<\/li>\n<\/ul>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Why Choose the 380 V Three-Phase Version?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The 220 V single-phase and 380 V three-phase versions are specified with the same hydraulic performance:<\/span><\/span><\/p>\n<ul>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Maximum operating pressure: 700 bar.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">First-stage flow rate: 14 L\/min.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">High-pressure flow rate: 2.8 L\/min.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Motor power: 3 kW.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Reservoir capacity: 30 litres.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Double-acting hydraulic circuit.<\/span><\/span><\/p>\n<\/li>\n<\/ul>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The main difference is the electrical supply and motor configuration.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>220 V vs 380 V Hydraulic Power Unit<\/b><\/span><\/span><\/p>\n<table width=\"653\" cellspacing=\"0\" cellpadding=\"1\">\n<tbody>\n<tr>\n<td width=\"169\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Feature<\/b><\/span><\/span><\/p>\n<\/td>\n<td width=\"238\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>220 V single-phase version<\/b><\/span><\/span><\/p>\n<\/td>\n<td width=\"238\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>380 V three-phase version<\/b><\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"169\">\n<p class=\"western\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Electrical supply<\/span><\/span><\/p>\n<\/td>\n<td width=\"238\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">220 V single-phase<\/span><\/span><\/p>\n<\/td>\n<td width=\"238\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">380 V three-phase<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"169\">\n<p class=\"western\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Motor power<\/span><\/span><\/p>\n<\/td>\n<td width=\"238\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">3 kW<\/span><\/span><\/p>\n<\/td>\n<td width=\"238\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">3 kW<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"169\">\n<p class=\"western\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Specified high-pressure limit<\/span><\/span><\/p>\n<\/td>\n<td width=\"238\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">700 bar<\/span><\/span><\/p>\n<\/td>\n<td width=\"238\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">700 bar<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"169\">\n<p class=\"western\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">First-stage flow rate<\/span><\/span><\/p>\n<\/td>\n<td width=\"238\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">14 L\/min<\/span><\/span><\/p>\n<\/td>\n<td width=\"238\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">14 L\/min<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"169\">\n<p class=\"western\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">High-pressure flow rate<\/span><\/span><\/p>\n<\/td>\n<td width=\"238\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">2.8 L\/min<\/span><\/span><\/p>\n<\/td>\n<td width=\"238\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">2.8 L\/min<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"169\">\n<p class=\"western\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Approximate current<\/span><\/span><\/p>\n<\/td>\n<td width=\"238\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">15\u201318 A, as stated for the model<\/span><\/span><\/p>\n<\/td>\n<td width=\"238\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">6\u20137 A per phase, as stated for the model<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"169\">\n<p class=\"western\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Electrical connection<\/span><\/span><\/p>\n<\/td>\n<td width=\"238\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Dedicated circuit suitable for the motor<\/span><\/span><\/p>\n<\/td>\n<td width=\"238\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Compatible three-phase circuit<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"169\">\n<p class=\"western\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Starting characteristics<\/span><\/span><\/p>\n<\/td>\n<td width=\"238\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Depend on motor and starting arrangement<\/span><\/span><\/p>\n<\/td>\n<td width=\"238\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Depend on motor and starting arrangement<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"169\">\n<p class=\"western\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Suitable installation<\/span><\/span><\/p>\n<\/td>\n<td width=\"238\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Sites with a suitable single-phase supply<\/span><\/span><\/p>\n<\/td>\n<td width=\"238\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Sites with a suitable three-phase supply<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><i>Current values and circuit protection are indicative and must be confirmed against the motor nameplate, wiring diagram, starting method and installation conditions. The 380 V version cannot be connected directly to a standard 220 V single-phase supply.<\/i><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Practical Advantages of Three-Phase Power<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Where a suitable three-phase supply is available, a three-phase motor can offer operational advantages:<\/span><\/span><\/p>\n<ul>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">More balanced motor torque compared with a conventional single-phase motor.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">No single-phase starting capacitor when the motor is configured as a standard three-phase induction motor.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Lower current per phase than the corresponding single-phase arrangement, subject to the actual motor and supply.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">A practical fit for industrial workshops already equipped with three-phase power.<\/span><\/span><\/p>\n<\/li>\n<\/ul>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">These characteristics can make the three-phase configuration attractive for equipment used frequently throughout a shift. However, actual motor temperature, service life and energy consumption depend on the motor design, load, duty cycle, ventilation and maintenance.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Our recommendation:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> if your facility has a suitable 380 V three-phase supply, this version is worth considering. If only a suitable 220 V single-phase supply is available, choose the corresponding 220 V model instead. Its specified hydraulic performance is the same.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Important During Initial Installation: Check Motor Rotation<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Correct phase sequence is essential for a three-phase motor driving a hydraulic pump.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Depending on the motor and pump configuration, an incorrect phase sequence can cause the motor to rotate in the wrong direction. The pump may then fail to deliver oil as intended, and operating it incorrectly can damage hydraulic components.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Recommended Commissioning Procedure<\/b><\/span><\/span><\/p>\n<ol>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Have a qualified electrician make the electrical connection.<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> Verify the supply voltage, phase configuration, protective earthing and circuit protection.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Check the oil level before starting.<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> Fill the reservoir to the level specified by the manufacturer using the approved hydraulic oil.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Verify the motor&#8217;s rotation direction.<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> Follow the manufacturer&#8217;s commissioning instructions and any rotation indicator on the motor.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Perform the initial test in accordance with the manual.<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> Confirm that the motor and pump operate correctly and that the system develops pressure as specified.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Stop the unit if pressure does not build as expected.<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> Do not continue running the pump in an attempt to force it to work.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Have the electrician correct the phase sequence if necessary.<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> Any changes to the electrical connections must be made with the equipment safely isolated.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Proceed to normal operation only after correct rotation and hydraulic operation have been confirmed.<\/b><\/span><\/span><\/p>\n<\/li>\n<\/ol>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Do not rely on the pressure gauge alone to determine motor rotation. The installation and commissioning procedure must follow the equipment manual.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">CraftOil can provide guidance on model selection and connection questions before purchase.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>What Does 3 kW Mean for Hydraulic Cycle Time?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The high-pressure flow rate affects how quickly oil is delivered to the cylinder while the pump operates at its high-pressure stage.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The following estimates compare the stated flow rates of the CraftOil power-unit range.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>High-Pressure Flow Rate Comparison<\/b><\/span><\/span><\/p>\n<table width=\"607\" cellspacing=\"0\" cellpadding=\"1\">\n<tbody>\n<tr>\n<td width=\"86\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><b>Motor power<\/b><\/span><\/p>\n<\/td>\n<td width=\"152\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><b>High-pressure flow rate<\/b><\/span><\/p>\n<\/td>\n<td width=\"185\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><b>Approx. time to deliver 0.5 L<\/b><\/span><\/p>\n<\/td>\n<td width=\"174\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><b>Approx. time to deliver 1 L<\/b><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">0.75 kW<\/span><\/span><\/p>\n<\/td>\n<td width=\"152\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">0.9 L\/min<\/span><\/span><\/p>\n<\/td>\n<td width=\"185\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">33 sec<\/span><\/span><\/p>\n<\/td>\n<td width=\"174\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">67 sec<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">1.5 kW<\/span><\/span><\/p>\n<\/td>\n<td width=\"152\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">1.7 L\/min<\/span><\/span><\/p>\n<\/td>\n<td width=\"185\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">18 sec<\/span><\/span><\/p>\n<\/td>\n<td width=\"174\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">35 sec<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">3 kW<\/span><\/span><\/p>\n<\/td>\n<td width=\"152\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">2.8 L\/min<\/span><\/span><\/p>\n<\/td>\n<td width=\"185\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">11 sec<\/span><\/span><\/p>\n<\/td>\n<td width=\"174\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">21 sec<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">These values are theoretical estimates based on oil volume divided by the specified flow rate. Actual cylinder movement depends on operating pressure, cylinder dimensions, effective chamber volume, hydraulic losses and operating conditions.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">For example, the theoretical time to deliver 0.5 litres at the high-pressure stage is approximately 11 seconds at 2.8 L\/min, compared with 33 seconds at 0.9 L\/min.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">In repeated production operations, shorter working strokes can contribute to improved throughput. The actual time savings for a complete cycle depend on the connected machine and its operating sequence.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Double-Acting Hydraulic Circuit<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">This hydraulic power unit is designed for compatible double-acting hydraulic cylinders.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">A double-acting cylinder has two working chambers. Hydraulic oil is directed alternately to the piston side and rod side, allowing controlled movement in both directions.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The unit uses two working lines, A and B, with a manual two-position directional valve to switch the hydraulic flow.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>When Is a Double-Acting Power Unit Required?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Choose this configuration when:<\/span><\/span><\/p>\n<ul>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Your hydraulic cylinder has two working ports.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The rod must retract under hydraulic pressure.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">You need controlled movement in both directions.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The application requires a powered return stroke.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Your equipment uses a compatible double-acting hydraulic circuit.<\/span><\/span><\/p>\n<\/li>\n<\/ul>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Typical applications include hydraulic presses, pipe benders, bearing pullers and industrial fixtures with double-acting cylinders.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Quick compatibility check:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> a cylinder with two ports may indicate a double-acting design, but the port count alone is not conclusive. Confirm the cylinder type, port functions, valve arrangement and pressure rating in the equipment documentation.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">If you are unsure, send CraftOil a photograph of the cylinder, its identification plate and the hydraulic connections. We can help you assess compatibility.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>30 L Hydraulic Reservoir: Capacity and Temperature Management<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The 30-litre reservoir supplies oil to the connected hydraulic system and helps manage temperature during operation. Its suitability depends on the equipment&#8217;s oil requirements, operating cycle and heat generation.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Oil Volume and Equipment Compatibility<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">As a preliminary sizing guideline, the oil available in the system should exceed the required working oil volume by approximately 20\u201330%, subject to the hydraulic system design and manufacturer&#8217;s instructions.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">A 30 L reservoir may therefore be suitable for certain systems with an estimated working oil requirement of approximately 23\u201324 litres. This is an indicative example, not a universal maximum cylinder volume.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">For a double-acting cylinder, consider the effective oil volume required by both chambers and the complete operating cycle. Also account for the permitted tank fill level, minimum oil level and any other hydraulic components in the circuit.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Oil Temperature During Intensive Operation<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">A common preliminary reservoir-sizing guideline is approximately three to five times the pump&#8217;s nominal flow per minute. At 14 L\/min, this would suggest a reservoir of roughly 42\u201370 litres.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">This is a rule of thumb rather than a universal requirement. Actual reservoir sizing depends on pump efficiency, pressure, operating cycle, ambient temperature, cooling conditions and the hydraulic system design.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The 30 L tank may be suitable for short or intermittent cycles. During intensive or continuous operation, oil temperature should be monitored carefully.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Recommended practices:<\/b><\/span><\/span><\/p>\n<ul>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Monitor oil temperature during repeated or high-load cycles.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Avoid unnecessary pump operation when the system is not performing useful work.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Allow cooling periods if the oil temperature approaches or exceeds the manufacturer&#8217;s permitted range.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Assess whether an oil cooler or heat exchanger is needed for continuous-duty applications.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Use only the oil grade specified for the power unit.<\/span><\/span><\/p>\n<\/li>\n<\/ul>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The three-phase motor configuration may offer motor-operating advantages, but it does not eliminate hydraulic heat generation or guarantee a lower overall oil temperature.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">For continuous or round-the-clock operation, contact CraftOil to discuss the actual duty cycle and cooling requirements.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Technical Specifications<\/b><\/span><\/span><\/p>\n<table width=\"651\" cellspacing=\"0\" cellpadding=\"1\">\n<tbody>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Parameter<\/b><\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Specification<\/b><\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Equipment type<\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Mobile electric-hydraulic power unit<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Hydraulic circuit<\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Double-acting, two-line<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Drive<\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Three-phase electric motor<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Motor power<\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">3 kW<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Supply voltage<\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">380 V, three-phase<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Pump type<\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Two-stage hydraulic pump<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Maximum operating pressure<\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">70 MPa \/ 700 bar<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">First-stage pressure<\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">2 MPa<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Second-stage pressure<\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">70 MPa<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">First-stage flow rate<\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">14 L\/min<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">High-pressure flow rate<\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">2.8 L\/min<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Reservoir capacity<\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">30 L<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Approximate current<\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">6\u20137 A per phase, subject to confirmation<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Recommended circuit protection<\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Three-pole 10\u201316 A, subject to motor and installation requirements<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Motor control<\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Remote control<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Directional valve<\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Manual, two-position<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Pressure gauge<\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Glycerine-filled, scale up to 1,000 bar<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">High-pressure hose length<\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">2 m<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Weight<\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">51 kg<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Warranty<\/span><\/span><\/p>\n<\/td>\n<td width=\"434\">\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">3 months, as specified for this model<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><i>Electrical protection, cable size, motor current and connection details must be confirmed against the nameplate, wiring diagram, local electrical regulations and the actual installation.<\/i><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Pressure Gauge: 1,000 Bar Scale, 700 Bar Maximum Pressure<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The supplied glycerine-filled pressure gauge has a scale extending to 1,000 bar. The hydraulic power unit&#8217;s specified maximum operating pressure remains <\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>700 bar<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">These are two different specifications:<\/span><\/span><\/p>\n<ul>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>700 bar<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> is the stated maximum operating pressure of the power unit.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>1,000 bar<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> is the upper limit of the pressure gauge&#8217;s scale.<\/span><\/span><\/p>\n<\/li>\n<\/ul>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">A gauge with a higher scale limit does not increase the pressure rating of the power unit.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Glycerine helps dampen needle vibration and can improve readability in applications with mechanical pulsation. Always ensure that the power unit, hoses, fittings, valves, cylinder and other connected components are rated for the intended operating pressure.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The maximum permitted pressure of the lowest-rated component must never be exceeded.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Remote Control for Convenient Operation<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The remote control allows the operator to start and stop the power unit from the working position, according to the supplied control configuration.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Remote operation can be useful for workshop applications where the operator needs to remain near the connected equipment. However, it does not replace appropriate guarding, safe positioning, pressure checks or the manufacturer&#8217;s operating procedures.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Before each working cycle, confirm that the hydraulic lines are correctly connected and all components are suitable for the intended pressure.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Package Contents<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The standard package includes:<\/span><\/span><\/p>\n<ul>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">CraftOil double-acting hydraulic power unit, 3 kW, 380 V.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">High-pressure hydraulic hose, 2 m.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Quick-release hydraulic coupling.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Glycerine-filled pressure gauge, scale up to 1,000 bar.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Pressure gauge adapter.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Remote control.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Operating instructions.<\/span><\/span><\/p>\n<\/li>\n<\/ul>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Hydraulic oil is not included.<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> The reservoir capacity is 30 litres. The actual filling quantity depends on the permitted oil level and the hydraulic circuit. Contact CraftOil for advice on selecting the correct oil grade.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Applications<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The CraftOil 3 kW three-phase double-acting hydraulic power unit may be suitable for compatible equipment such as:<\/span><\/span><\/p>\n<ul>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Hydraulic cable lug crimping machines.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Hydraulic cable cutters.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Busbar bending machines.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Industrial hydraulic presses, including cable-processing presses.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Double-acting hydraulic cylinders.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Compatible hydraulic jacks.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Hydraulic pipe benders.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Bearing and pulley pullers.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Industrial hydraulic fixtures and pressing systems.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Other hydraulic machinery designed for the unit&#8217;s pressure, flow rate and connection configuration.<\/span><\/span><\/p>\n<\/li>\n<\/ul>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Who Is This Model Best For?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">This version is particularly worth considering for:<\/span><\/span><\/p>\n<ul>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Manufacturing workshops with a suitable three-phase supply.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Electrical installation companies performing cable crimping in batches.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Industrial maintenance and repair departments.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Service centres equipped with compatible three-phase power.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Production lines where hydraulic equipment operates repeatedly throughout a shift.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Facilities using compatible double-acting cylinders that require higher oil flow.<\/span><\/span><\/p>\n<\/li>\n<\/ul>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The best choice depends on the cylinder, pressure requirements, working oil volume, number of cycles per shift, electrical installation and duty cycle.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>CraftOil Hydraulic Power Unit Range<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Compare the main specifications to choose the appropriate configuration.<\/span><\/span><\/p>\n<table width=\"653\" cellspacing=\"0\" cellpadding=\"1\">\n<tbody>\n<tr>\n<td width=\"129\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><b>Model<\/b><\/span><\/p>\n<\/td>\n<td width=\"106\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><b>Hydraulic circuit<\/b><\/span><\/p>\n<\/td>\n<td width=\"72\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><b>Motor power<\/b><\/span><\/p>\n<\/td>\n<td width=\"109\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><b>Supply<\/b><\/span><\/p>\n<\/td>\n<td width=\"188\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><b>Flow rate, first\/high-pressure stage<\/b><\/span><\/p>\n<\/td>\n<td width=\"37\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><b>Tank<\/b><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"129\">\n<p class=\"western\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">DYB-63A \/ DYB-63H<\/span><\/span><\/p>\n<\/td>\n<td width=\"106\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Single-acting<\/span><\/span><\/p>\n<\/td>\n<td width=\"72\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">0.75 kW<\/span><\/span><\/p>\n<\/td>\n<td width=\"109\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">220 V<\/span><\/span><\/p>\n<\/td>\n<td width=\"188\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">5 \/ 0.9 L\/min<\/span><\/span><\/p>\n<\/td>\n<td width=\"37\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">7 L<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"129\">\n<p class=\"western\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">HHB-700AB<\/span><\/span><\/p>\n<\/td>\n<td width=\"106\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Double-acting<\/span><\/span><\/p>\n<\/td>\n<td width=\"72\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">0.75 kW<\/span><\/span><\/p>\n<\/td>\n<td width=\"109\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">220 V<\/span><\/span><\/p>\n<\/td>\n<td width=\"188\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">5 \/ 0.9 L\/min<\/span><\/span><\/p>\n<\/td>\n<td width=\"37\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">7 L<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"129\">\n<p class=\"western\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">DB-150S1<\/span><\/span><\/p>\n<\/td>\n<td width=\"106\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Single-acting<\/span><\/span><\/p>\n<\/td>\n<td width=\"72\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">1.5 kW<\/span><\/span><\/p>\n<\/td>\n<td width=\"109\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">220 V<\/span><\/span><\/p>\n<\/td>\n<td width=\"188\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">7.9 \/ 1.7 L\/min<\/span><\/span><\/p>\n<\/td>\n<td width=\"37\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">10 L<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"129\">\n<p class=\"western\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">DB150-S2<\/span><\/span><\/p>\n<\/td>\n<td width=\"106\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Double-acting<\/span><\/span><\/p>\n<\/td>\n<td width=\"72\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">1.5 kW<\/span><\/span><\/p>\n<\/td>\n<td width=\"109\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">220 V<\/span><\/span><\/p>\n<\/td>\n<td width=\"188\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">7.9 \/ 1.7 L\/min<\/span><\/span><\/p>\n<\/td>\n<td width=\"37\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">10 L<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"129\">\n<p class=\"western\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">1.5 kW \/ 30 L<\/span><\/span><\/p>\n<\/td>\n<td width=\"106\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Double-acting<\/span><\/span><\/p>\n<\/td>\n<td width=\"72\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">1.5 kW<\/span><\/span><\/p>\n<\/td>\n<td width=\"109\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">220 V<\/span><\/span><\/p>\n<\/td>\n<td width=\"188\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">7.9 \/ 1.7 L\/min<\/span><\/span><\/p>\n<\/td>\n<td width=\"37\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">30 L<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"129\">\n<p class=\"western\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">3 kW \/ 30 L, 220 V<\/span><\/span><\/p>\n<\/td>\n<td width=\"106\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Double-acting<\/span><\/span><\/p>\n<\/td>\n<td width=\"72\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">3 kW<\/span><\/span><\/p>\n<\/td>\n<td width=\"109\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">220 V<\/span><\/span><\/p>\n<\/td>\n<td width=\"188\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">14 \/ 2.8 L\/min<\/span><\/span><\/p>\n<\/td>\n<td width=\"37\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">30 L<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"129\">\n<p class=\"western\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">3 kW \/ 30 L, 380 V<\/span><\/span><\/p>\n<\/td>\n<td width=\"106\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Double-acting<\/span><\/span><\/p>\n<\/td>\n<td width=\"72\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">3 kW<\/span><\/span><\/p>\n<\/td>\n<td width=\"109\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">380 V, three-phase<\/span><\/span><\/p>\n<\/td>\n<td width=\"188\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">14 \/ 2.8 L\/min<\/span><\/span><\/p>\n<\/td>\n<td width=\"37\">\n<p class=\"western\" align=\"center\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">30 L<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><i>The table summarises the supplied model specifications. Confirm the exact model code, connection details and electrical requirements before ordering.<\/i><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>How to Choose the Right Model<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>1. Do you have a three-phase electrical supply?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">If a suitable 380 V three-phase supply is available, this version may be a good fit. If not, consider the corresponding 220 V model.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>2. Does your cylinder require a double-acting circuit?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Check the cylinder documentation and hydraulic connections. A double-acting cylinder requires a compatible power unit and valve arrangement.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>3. How frequently will the equipment operate?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">For repeated operations where higher flow can reduce working-stroke time, the 3 kW model may be appropriate. Lower-powered models may be sufficient for occasional tasks.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>4. What is the hydraulic oil requirement?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Select the reservoir based on the actual hydraulic circuit and cylinder requirements. Do not choose tank capacity by cylinder tonnage alone.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Compatibility with CraftOil Hydraulic Presses<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">CraftOil manufactures hydraulic presses in 30-tonne and 50-tonne configurations and has practical experience with hydraulic equipment in its own production environment.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The correct power unit depends on the press&#8217;s cylinder, operating pressure, flow requirements, hydraulic circuit, connections and electrical supply. The fact that a press has a particular force rating does not, by itself, establish compatibility.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Before connecting this power unit, confirm:<\/span><\/span><\/p>\n<ul>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Cylinder type and hydraulic port configuration.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Required operating pressure.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Required oil flow and working volume.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Valve and quick-release coupling compatibility.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Hose and fitting pressure ratings.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Three-phase supply and motor connection requirements.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Permitted operating cycle and oil temperature limits.<\/span><\/span><\/p>\n<\/li>\n<\/ul>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Contact CraftOil with the press model and technical details. We can help assess whether this 3 kW, 380 V unit is appropriate or whether another configuration would better suit your application.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Recommended Hydraulic Oil<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The exact hydraulic oil specification must be confirmed in the product manual.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The supplied source information indicates industrial hydraulic oils in the ISO VG 32 or ISO VG 46 viscosity classes, including compatible HLP 32\/HLP 46 products and equivalent oils approved for the application.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Before filling the reservoir:<\/b><\/span><\/span><\/p>\n<ul>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Confirm the oil grade:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> follow the manufacturer&#8217;s instructions and operating-temperature requirements.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Check the fill level:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> the nominal tank capacity is 30 litres, but the permitted oil level must follow the manual.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Keep the oil clean:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> use suitable filtration when filling.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Monitor temperature:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> intensive operation can increase oil temperature.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Follow maintenance instructions:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> inspect the oil and replace it at the intervals specified for the equipment and working conditions.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Do not mix oils indiscriminately:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> confirm compatibility before changing oil type or manufacturer.<\/span><\/span><\/p>\n<\/li>\n<\/ul>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">CraftOil can help you identify the appropriate hydraulic oil for the unit and your application.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Safety and Operation<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">A hydraulic system operating at 700 bar requires correct installation, pressure-rated components and trained operators.<\/span><\/span><\/p>\n<ul>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Have a qualified electrician install the three-phase electrical connection.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Confirm protective earthing and suitable circuit protection.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Verify the motor&#8217;s rotation direction during initial commissioning.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Check the oil level before starting the pump.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Inspect hydraulic hoses and fittings before each use. Replace damaged, cracked, swollen or leaking components.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Confirm that lines A and B are connected to the correct ports.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Never disconnect a quick-release coupling while the system is pressurised.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Never exceed the rated pressure of the power unit, hoses, cylinder, valves or fittings.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Never use your hands to locate a high-pressure oil leak. High-pressure fluid injection injuries can be severe.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Wear suitable eye protection and follow the equipment manufacturer&#8217;s operating procedures.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Depressurise the system according to the manual before maintenance or disconnection.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The unit weighs 51 kg. Use suitable lifting equipment or a safe team-lifting procedure.<\/span><\/span><\/p>\n<\/li>\n<\/ul>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The pressure gauge&#8217;s 1,000 bar scale does not permit the power unit to operate above its specified 700 bar maximum.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Warranty, Spare Parts and Service<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">CraftOil provides support for this model under the following terms:<\/span><\/span><\/p>\n<ul>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Warranty:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> 3 months, as specified for this product.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Spare parts in Ukraine:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> commonly required components, including seals, pressure gauges, hoses, quick-release couplings, directional valves and remote controls, subject to current stock.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Technical assistance:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> guidance on connection, phase sequence and setup by phone, Viber or Telegram.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Collection:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> from the CraftOil warehouse in Kharkiv.<\/span><\/span><\/p>\n<\/li>\n<li>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Delivery within Ukraine:<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> dispatch by Nova Poshta.<\/span><\/span><\/p>\n<\/li>\n<\/ul>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">For international orders, contact CraftOil to confirm shipping availability, delivery terms and service options for your destination.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Why Buy from CraftOil?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Practical manufacturing experience.<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> CraftOil manufactures hydraulic presses and understands the importance of matching a power unit to the cylinder, circuit and operating conditions.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Help with commissioning.<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> We can explain the key checks required for a three-phase installation, including the importance of verifying motor rotation before normal operation.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Honest equipment selection.<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> The highest motor power is not always the best option. If a 1.5 kW model or the 220 V version is more suitable for your needs, we will help you assess that choice.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Service and spare parts in Ukraine.<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> Access to technical assistance and commonly used replacement components can help reduce unnecessary downtime.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Support with hydraulic oil selection.<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> We can help identify the appropriate oil grade and filling requirements based on the product documentation.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Convenient ordering.<\/b><\/span><\/span><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"> Payment options may include card payment, bank transfer using company details and instalment payment, subject to current availability and terms.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Frequently Asked Questions<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>What is the advantage of the 380 V version over the 220 V model?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The specified hydraulic performance is the same. The 380 V version uses a three-phase supply, which can provide balanced motor operation and lower current per phase when correctly configured. It is intended for facilities with a suitable three-phase electrical connection.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Can I connect the 380 V power unit to a standard 220 V single-phase outlet?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">No. This version requires a compatible three-phase supply. If your facility has only single-phase power, consider the corresponding 220 V model.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>What should I do if the motor runs but the system does not build pressure?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Stop the unit and follow the commissioning instructions. Incorrect motor rotation caused by the phase sequence is one possible explanation, but it is not the only one. Have a qualified electrician verify the electrical connection and confirm correct pump operation before restarting.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>What circuit breaker is required?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The source specifications indicate an approximate current of 6\u20137 A per phase and a three-pole 10\u201316 A breaker. The final breaker rating and cable size must be selected by a qualified electrician using the motor nameplate, starting current, wiring diagram and installation conditions.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>How much faster is the 3 kW model than the 0.75 kW model?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">At the specified high-pressure stage, the 3 kW unit delivers 2.8 L\/min compared with 0.9 L\/min for the 0.75 kW model. This is approximately 3.1 times the flow rate. Actual working-stroke and complete-cycle times depend on the connected equipment.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Is a 30 L reservoir sufficient at 14 L\/min?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">It may be suitable for certain intermittent applications. For intensive or continuous operation, monitor oil temperature and assess the system&#8217;s cooling requirements. Reservoir capacity alone does not establish continuous-duty suitability.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>What is the maximum operating pressure?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The specified maximum operating pressure is 700 bar (70 MPa). The gauge scale extends to 1,000 bar, but this does not increase the power unit&#8217;s pressure rating.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Which hydraulic oil should I use?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The source specifications indicate ISO VG 32 or ISO VG 46 industrial hydraulic oil, including compatible HLP products. Confirm the approved grade in the product manual before filling.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Is hydraulic oil included?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">No. Hydraulic oil is not included in the standard package.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>What is the warranty period?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">The specified warranty for this model is three months. Contact CraftOil for the applicable warranty conditions and service details.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Can I use this power unit with a CraftOil hydraulic press?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Potentially, provided the press&#8217;s cylinder, hydraulic circuit, pressure requirements, flow rate, connections and electrical supply are compatible. Contact CraftOil with your press model and technical details before connecting the unit.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Can CraftOil deliver outside Ukraine?<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Contact CraftOil to confirm international shipping availability, delivery terms and service options for your destination.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><b>Order Your CraftOil 3 kW, 380 V Hydraulic Power Unit<\/b><\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Looking for a three-phase double-acting hydraulic power unit with 700 bar maximum operating pressure, 14 L\/min first-stage flow and a 30 L reservoir?<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">Contact CraftOil before ordering. Tell us about your hydraulic cylinder, equipment, operating cycle and available three-phase supply. We will help you assess compatibility and determine whether this model is the right choice for your application.<\/span><\/span><\/p>\n<p class=\"western\" align=\"justify\"><span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\">CraftOil \u2014 hydraulic equipment backed by practical manufacturing experience and technical support.<\/span><\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>3 kW electric motor \u00b7 380 V three-phase supply \u00b7 700 bar maximum operating pressure \u00b7 30 L oil tank \u00b7 Double-acting hydraulic circuit Industrial hydraulic power for demanding applications and repeated work cycles. The CraftOil 3 kW three-phase double-acting hydraulic power unit is designed for industrial workshops, manufacturing facilities and service centres that require [&hellip;]<\/p>\n","protected":false},"featured_media":61688,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[173,236],"product_tag":[],"class_list":["post-61696","product","type-product","status-publish","has-post-thumbnail","product_cat-equipment-en","product_cat-hydraulic-power-units","first","instock","shipping-taxable","purchasable","product-type-simple"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>3 kW Hydraulic Power Unit 380 V, 700 Bar, 30 L | CraftOil<\/title>\n<meta name=\"description\" content=\"Buy a 3 kW three-phase hydraulic power unit from CraftOil. 380 V, 700 bar, 14 L\/min first-stage flow, 2.8 L\/min high-pressure flow and 30 L tank. Double-acting hydraulic circuit, remote control and service support in Ukraine.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.craftoil.net\/en\/product\/maslostantsiia-hidravlichna-dvopotokova-3-kvt-380-v-bak-30-l\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"3 kW Hydraulic Power Unit 380 V, 700 Bar, 30 L | CraftOil\" \/>\n<meta property=\"og:description\" content=\"Buy a 3 kW three-phase hydraulic power unit from CraftOil. 380 V, 700 bar, 14 L\/min first-stage flow, 2.8 L\/min high-pressure flow and 30 L tank. Double-acting hydraulic circuit, remote control and service support in Ukraine.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.craftoil.net\/en\/product\/maslostantsiia-hidravlichna-dvopotokova-3-kvt-380-v-bak-30-l\/\" \/>\n<meta property=\"og:site_name\" content=\"CraftOil\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-06T15:48:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.craftoil.net\/wp-content\/uploads\/2026\/11\/1-6.png\" \/>\n\t<meta property=\"og:image:width\" content=\"768\" \/>\n\t<meta property=\"og:image:height\" content=\"497\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"17 minutes\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"3 kW Hydraulic Power Unit 380 V, 700 Bar, 30 L | CraftOil","description":"Buy a 3 kW three-phase hydraulic power unit from CraftOil. 380 V, 700 bar, 14 L\/min first-stage flow, 2.8 L\/min high-pressure flow and 30 L tank. Double-acting hydraulic circuit, remote control and service support in Ukraine.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.craftoil.net\/en\/product\/maslostantsiia-hidravlichna-dvopotokova-3-kvt-380-v-bak-30-l\/","og_locale":"en_US","og_type":"article","og_title":"3 kW Hydraulic Power Unit 380 V, 700 Bar, 30 L | CraftOil","og_description":"Buy a 3 kW three-phase hydraulic power unit from CraftOil. 380 V, 700 bar, 14 L\/min first-stage flow, 2.8 L\/min high-pressure flow and 30 L tank. Double-acting hydraulic circuit, remote control and service support in Ukraine.","og_url":"https:\/\/www.craftoil.net\/en\/product\/maslostantsiia-hidravlichna-dvopotokova-3-kvt-380-v-bak-30-l\/","og_site_name":"CraftOil","article_modified_time":"2026-11-06T15:48:43+00:00","og_image":[{"width":768,"height":497,"url":"https:\/\/www.craftoil.net\/wp-content\/uploads\/2026\/11\/1-6.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"17 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":["WebPage","ItemPage"],"@id":"https:\/\/www.craftoil.net\/en\/product\/maslostantsiia-hidravlichna-dvopotokova-3-kvt-380-v-bak-30-l\/","url":"https:\/\/www.craftoil.net\/en\/product\/maslostantsiia-hidravlichna-dvopotokova-3-kvt-380-v-bak-30-l\/","name":"3 kW Hydraulic Power Unit 380 V, 700 Bar, 30 L | CraftOil","isPartOf":{"@id":"https:\/\/www.craftoil.net\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.craftoil.net\/en\/product\/maslostantsiia-hidravlichna-dvopotokova-3-kvt-380-v-bak-30-l\/#primaryimage"},"image":{"@id":"https:\/\/www.craftoil.net\/en\/product\/maslostantsiia-hidravlichna-dvopotokova-3-kvt-380-v-bak-30-l\/#primaryimage"},"thumbnailUrl":"https:\/\/www.craftoil.net\/wp-content\/uploads\/2026\/11\/1-6.png","datePublished":"2026-11-06T15:37:32+00:00","dateModified":"2026-11-06T15:48:43+00:00","description":"Buy a 3 kW three-phase hydraulic power unit from CraftOil. 380 V, 700 bar, 14 L\/min first-stage flow, 2.8 L\/min high-pressure flow and 30 L tank. Double-acting hydraulic circuit, remote control and service support in Ukraine.","breadcrumb":{"@id":"https:\/\/www.craftoil.net\/en\/product\/maslostantsiia-hidravlichna-dvopotokova-3-kvt-380-v-bak-30-l\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.craftoil.net\/en\/product\/maslostantsiia-hidravlichna-dvopotokova-3-kvt-380-v-bak-30-l\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.craftoil.net\/en\/product\/maslostantsiia-hidravlichna-dvopotokova-3-kvt-380-v-bak-30-l\/#primaryimage","url":"https:\/\/www.craftoil.net\/wp-content\/uploads\/2026\/11\/1-6.png","contentUrl":"https:\/\/www.craftoil.net\/wp-content\/uploads\/2026\/11\/1-6.png","width":768,"height":497},{"@type":"BreadcrumbList","@id":"https:\/\/www.craftoil.net\/en\/product\/maslostantsiia-hidravlichna-dvopotokova-3-kvt-380-v-bak-30-l\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u0413\u043e\u043b\u043e\u0432\u043d\u0430","item":"https:\/\/www.craftoil.net\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.craftoil.net\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"3 kW Three-Phase Double-Acting Hydraulic Power Unit, 380 V, 30 L Tank"}]},{"@type":"WebSite","@id":"https:\/\/www.craftoil.net\/en\/#website","url":"https:\/\/www.craftoil.net\/en\/","name":"CraftOil","description":"CraftOil","publisher":{"@id":"https:\/\/www.craftoil.net\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.craftoil.net\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.craftoil.net\/en\/#organization","name":"CraftOil","url":"https:\/\/www.craftoil.net\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.craftoil.net\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.craftoil.net\/wp-content\/uploads\/2022\/06\/Craft-Oil-logo-1.png","contentUrl":"https:\/\/www.craftoil.net\/wp-content\/uploads\/2022\/06\/Craft-Oil-logo-1.png","width":149,"height":149,"caption":"CraftOil"},"image":{"@id":"https:\/\/www.craftoil.net\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.craftoil.net\/en\/wp-json\/wp\/v2\/product\/61696","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.craftoil.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.craftoil.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.craftoil.net\/en\/wp-json\/wp\/v2\/comments?post=61696"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.craftoil.net\/en\/wp-json\/wp\/v2\/media\/61688"}],"wp:attachment":[{"href":"https:\/\/www.craftoil.net\/en\/wp-json\/wp\/v2\/media?parent=61696"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.craftoil.net\/en\/wp-json\/wp\/v2\/product_brand?post=61696"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.craftoil.net\/en\/wp-json\/wp\/v2\/product_cat?post=61696"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.craftoil.net\/en\/wp-json\/wp\/v2\/product_tag?post=61696"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}